Rincian Produk
Tempat asal: Cina
Nama merek: Qifan
Sertifikasi: ISO9001, CCC, RoHS
Nomor model: AAC Daisy
Ketentuan Pembayaran & Pengiriman
Kuantitas min Order: 100m
Harga: usd3-8/meter
Kemasan rincian: drum kayuDetail Kemasan Kemasan Dalam: Gulungan kayu, Gulungan plastik, dan Gulungan Kertas Kemasan
Waktu pengiriman: 30-45 hari
Syarat-syarat pembayaran: D/A, D/P, L/C, T/T, Western Union, MoneyGram
Menyediakan kemampuan: 50000K Meter/per Bulan
Nomor model.: |
AAC Daisy |
Bentuk Bahan: |
kawat bulat |
Rentang Aplikasi: |
Saluran Listrik Transmisi |
Merek: |
QIFAN |
Jaminan: |
10 tahun |
QC: |
200 |
Warna: |
Perak |
Paket Pengangkutan: |
Gulungan dan Drum |
Spesifikasi: |
1/0 2/0 4/0 |
Merek dagang: |
QIFAN |
Asal usul: |
Cina |
Kode HS: |
761490000 |
Menyediakan kemampuan: |
50ton Per Hari |
Jenis: |
telanjang |
Tipe Konduktor: |
terdampar |
Aplikasi: |
Atas |
Bahan Konduktor: |
Aluminium |
Bahan Sarung: |
telanjang |
Bahan isolasi: |
telanjang |
Nomor model.: |
AAC Daisy |
Bentuk Bahan: |
kawat bulat |
Rentang Aplikasi: |
Saluran Listrik Transmisi |
Merek: |
QIFAN |
Jaminan: |
10 tahun |
QC: |
200 |
Warna: |
Perak |
Paket Pengangkutan: |
Gulungan dan Drum |
Spesifikasi: |
1/0 2/0 4/0 |
Merek dagang: |
QIFAN |
Asal usul: |
Cina |
Kode HS: |
761490000 |
Menyediakan kemampuan: |
50ton Per Hari |
Jenis: |
telanjang |
Tipe Konduktor: |
terdampar |
Aplikasi: |
Atas |
Bahan Konduktor: |
Aluminium |
Bahan Sarung: |
telanjang |
Bahan isolasi: |
telanjang |
Nomor Kode | Daerah | Jumlah Kabel | Diameter | Massa linier | Kekuatan Nominal | Max.D.C.Resistensi pada 20oC | |
mm2 | Kawat | Kondisi. | kg/km | kN | Ω/km | ||
10 | 10 | 7 | 1.35 | 4.05 | 27.4 | 1.95 | 2.8633 |
16 | 16 | 7 | 1.71 | 5.12 | 43.8 | 3.04 | 1.7896 |
25 | 25 | 7 | 2.13 | 6.4 | 68.4 | 4.5 | 1.1453 |
40 | 40 | 7 | 2.7 | 8.09 | 109.4 | 6.8 | 0.7158 |
63 | 63 | 7 | 3.39 | 10.2 | 172.3 | 10.39 | 0.4545 |
100 | 100 | 19 | 2.59 | 12.9 | 274.8 | 17 | 0.2877 |
125 | 125 | 19 | 2.89 | 14.5 | 343.6 | 21.25 | 0.2302 |
160 | 160 | 19 | 3.27 | 16.4 | 439.8 | 26.4 | 0.1798 |
200 | 200 | 19 | 3.66 | 18.3 | 549.7 | 32 | 0.1439 |
250 | 250 | 19 | 4.09 | 20.5 | 687.1 | 40 | 0.1151 |
315 | 315 | 37 | 3.29 | 23 | 867.9 | 51.97 | 0.0916 |
400 | 400 | 37 | 3.71 | 26 | 1102 | 64 | 0.0721 |
450 | 450 | 37 | 3.94 | 27.5 | 1239.8 | 72 | 0.0641 |
500 | 500 | 37 | 4.15 | 29 | 1377.6 | 80 | 0.0577 |
560 | 560 | 37 | 4.39 | 30.7 | 1542.9 | 89.6 | 0.0515 |
630 | 630 | 61 | 3.63 | 32.6 | 1738.3 | 100.8 | 0.0458 |
710 | 710 | 61 | 3.85 | 34.6 | 1959.1 | 113.6 | 0.0407 |
800 | 800 | 61 | 4.09 | 36.8 | 2207.4 | 128 | 0.0361 |
900 | 900 | 61 | 4.33 | 39 | 2483.3 | 144 | 0.0321 |
1000 | 1000 | 61 | 4.57 | 41.1 | 2759.2 | 160 | 0.0289 |
1120 | 1120 | 91 | 3.96 | 43.5 | 3093.5 | 179.2 | 0.0258 |
1250 | 1250 | 91 | 4.18 | 46 | 3452.6 | 200 | 0.0231 |
1400 | 1400 | 91 | 4.43 | 48.7 | 3866.9 | 224 | 0.0207 |
1500 | 1500 | 91 | 4.58 | 50.4 | 4143.1 | 240 | 0.0193 |
Nama kode | Nominal | Nomor | Berpisah... | Secara keseluruhan | Berat badan | Pengecualian: | Max.D.C. Resistensi pada 20oC |
(mm2) | (mm) | (mm2) | (mm) | (kg/km) | DaN | Ω/km | |
Midge | 22 | 7/2.06 | 23.33 | 6.18 | 64 | 399 | 1.227 |
Aphis | 25 | 3/3.35 | 26.44 | 7.22 | 74 | 411 | 1.081 |
Nyamuk | 25 | 7/2.21 | 26.85 | 6.63 | 73 | 459 | 1.066 |
Bulat | 30 | 3/3.66 | 31.56 | 7.89 | 86 | 486 | 0.9082 |
Nyamuk | 35 | 7/2.59 | 36.88 | 7.77 | 101 | 603 | 0.7762 |
Burung Putri | 40 | 7/2.79 | 42.8 | 8.37 | 117 | 687 | 0.6689 |
Semut | 50 | 7/3.10 | 52.83 | 9.3 | 145 | 828 | 0.5419 |
Terbang | 60 | 7/3.40 | 63.55 | 10.2 | 174 | 990 | 0.4505 |
Bottle biru | 70 | 7/3.66 | 73.65 | 10.98 | 202 | 1134 | 0.3881 |
Telinga | 75 | 7/3.78 | 78.55 | 11.34 | 215 | 1194 | 0.3644 |
Tikus | 80 | 7/3.91 | 84.05 | 11.73 | 230 | 1278 | 0.3406 |
Clegg | 90 | 7/4.17 | 95.6 | 12.51 | 262 | 1453 | 0.2994 |
Angsa | 100 | 7/4.39 | 106 | 13.17 | 290 | 1600 | 0.2702 |
Kepiting | 100 | 19/2.67 | 106.4 | 13.35 | 293 | 1742 | 0.2704 |
Lebah | 125 | 7/4.90 | 132 | 14.7 | 361 | 1944 | 0.2169 |
Kriket | 150 | 7/5.36 | 157.9 | 16.08 | 432 | 2385 | 0.1818 |
Burung Hornet | 150 | 19/3.25 | 157.6 | 16.25 | 434 | 2570 | 0.1825 |
Caterpillar | 175 | 19/3.53 | 185.9 | 17.65 | 511 | 2863 | 0.1547 |
Chafer | 200 | 19/3.78 | 213.2 | 18.9 | 587 | 3240 | 0.1349 |
Laba-laba | 225 | 19/3.99 | 237.6 | 19.95 | 654 | 3601 | 0.1211 |
Kecoa | 250 | 19/4.22 | 265.7 | 21.1 | 731 | 4040 | 0.1083 |
Kupu-kupu | 300 | 19/4.65 | 322.7 | 23.25 | 888 | 4875 | 0.08916 |
Kupu-kupu | 350 | 19/5.00 | 373.1 | 25 | 1027 | 5637 | 0.07711 |
Drone | 350 | 37/3.58 | 372.4 | 25.06 | 1027 | 5745 | 0.07741 |
Tikus | 400 | 19/5.36 | 428.7 | 26.8 | 1180 | 6473 | 0.0671 |
Burung seratus kaki | 400 | 37/3.78 | 415.2 | 26.46 | 1145 | 6310 | 0.06944 |
Maybug | 450 | 37/4.09 | 486.1 | 28.63 | 1340 | 7401 | 0.05931 |
Kalajengking | 500 | 37/4.27 | 529.8 | 29.89 | 1461 | 7998 | 0.05441 |
Sikat | 600 | 37/4.65 | 628.3 | 32.55 | 1732 | 9495 | 0.04588 |
Tarantula | 750 | 37/5.23 | 794.9 | 36.61 | 2192 | 12010 | 0.03627 |
Nama Kode | Total Luas | Stranding dan diameter kawat mm |
Massa linier kg/km |
Secara keseluruhan Diameter mm |
Nominal Mematahkan Beban DaN |
Max. DC. Resistensi pada 20oC ≤Ω/k |
|
AWG atau MCM |
mm2 | ||||||
Peachbell | 6 | 13.29 | 7/1.554 | 37 | 4.67 | 249 | 2.1692 |
Bunga mawar | 4 | 21.16 | 7/1.961 | 58 | 5.89 | 396 | 1.3624 |
Iris | 2 | 33.61 | 7/2.474 | 93 | 7.42 | 597 | 0.8577 |
Pansy | 1 | 42.39 | 7/2.776 | 117 | 8.33 | 732 | 0.6801 |
PoPP | 1/0 | 53.48 | 7/3.119 | 147 | 9.36 | 873 | 0.5390 |
Aster | 2/0 | 67.42 | 7/3.503 | 186 | 10.51 | 1100 | 0.4276 |
Phlox | 3/0 | 85.03 | 7/3.932 | 234 | 11.80 | 1347 | 0.3390 |
Oxlip | 4/0 | 107.23 | 7/4.417 | 296 | 13.26 | 1698 | 0.2688 |
Valerian | 250 | 126.71 | 19/2.931 | 349 | 14.57 | 2062 | 0.2275 |
Sneezewort | 250 | 126.71 | 7/4.80 | 349 | 14.4 | 2007 | 0.2275 |
Laurel | 266.8 | 135.16 | 19/3.01 | 373 | 15.05 | 2200 | 0.2133 |
Daisy | 266.8 | 135.16 | 7/4.96 | 373 | 14.9 | 2141 | 0.2133 |
Buah peony | 300 | 152.0 | 19/3.193 | 419 | 15.97 | 2403 | 0.1896 |
Tulip | 336.4 | 170.45 | 19/3.381 | 470 | 16.91 | 2695 | 0.1691 |
Daffodil | 350 | 177.35 | 19/3.447 | 489 | 17.24 | 2804 | 0.1625 |
Canna | 397.5 | 201.42 | 19/3.673 | 555 | 18.36 | 3184 | 0.1431 |
Goldentuft | 450 | 228 | 19/3.909 | 629 | 19.55 | 3499 | 0.1264 |
Siring | 477 | 241.68 | 37/2.882 | 666 | 20.19 | 3849 | 0.1193 |
Kosmos | 477 | 241.68 | 19/4.023 | 666 | 20.12 | 3708 | 0.1193 |
Hyacinth | 500 | 253.35 | 37/2.951 | 698 | 20.65 | 4035 | 0.1138 |
Zinnia | 500 | 253.35 | 19/4.12 | 698 | 20.6 | 3888 | 0.1138 |
Dahlia | 556.5 | 282 | 19/4.346 | 777 | 21.73 | 4327 | 0.1022 |
Mistil | 556.5 | 282 | 37/3.114 | 777 | 21.79 | 4362 | 0.1022 |
Meadowsweet | 600 | 304 | 37/3.233 | 838 | 22.63 | 4703 | 0.0948 |
Anggrek | 636 | 322.25 | 37/3.33 | 888 | 23.31 | 4985 | 0.0894 |
Heuchera | 650 | 329.35 | 37/3.366 | 908 | 23.56 | 5095 | 0.0875 |
Bendera | 700 | 354.71 | 61/2.72 | 978 | 24.48 | 5146 | 0.0813 |
Nomor Kode | Luas yang Dihitung | Stranding dan kawat Diameter | Diameter keseluruhan | Massa linier | Pengecualian: | Max D.C.Resistance pada 20oC |
mm2 | mm2 | mm | mm | kg/km | DaN | Oh, km |
16 | 15.89 | 7/1.70 | 5.1 | 44 | 290 | 1.8018 |
25 | 24.25 | 7/2.10 | 6.3 | 67 | 425 | 1.1808 |
35 | 34.36 | 7/2 50 | 7.5 | 94 | 585 | 0.8332 |
50 | 49.48 | 7/3.00 | 9 | 135 | 810 | 0.5786 |
50 | 48.36 | 19/1.80 | 9 | 133 | 860 | 0.595 |
70 | 65.82 | 19/2.10 | 10.5 | 181 | 1150 | 0.4371 |
95 | 93.27 | 19/2.50 | 12.5 | 256 | 1595 | 0.3084 |
120 | 117 | 19/2.50 | 14 | 322 | 1910 | 0.2459 |
150 | 147.1 | 37/2.25 | 15.2 | 406 | 2570 | 0.196 |
185 | 181.6 | 37/2.50 | 17.5 | 501 | 3105 | 0.1587 |
240 | 242.54 | 61/2.25 | 20.2 | 670 | 4015 | 0.1191 |
300 | 299.43 | 61/2.50 | 22.5 | 827 | 4850 | 0.0965 |
400 | 400.14 | 61/2.89 | 26 | 1105 | 6190 | 0.07221 |
500 | 499.83 | 61/3.23 | 29.1 | 1381 | 7600 | 0.05781 |
625 | 626.2 | 91/2.96 | 32.6 | 1733 | 9690 | 0.04625 |
500 | 802.1 | 91/3.35 | 36.8 | 2219 | 12055 | 0.03611 |
1000 | 999.71 | 91/3.74 | 41.1 | 2766 | 14845 | 0.02897 |
Produk utama: Kabel listrik 220kv dan di bawahnya, kabel berlapis karet, kabel fotovoltaik, kabel khusus fotovoltaik, kabel kontrol, kabel komputer, kabel berantai aluminium inti baja,Kabel pra-cabang, kabel tegangan rendah bebas halogen yang ramah lingkungan, kabel pertambangan batubara, isolasi fluorosilikon Kabel tahan suhu tinggi, kabel pelindung, kabel untuk peralatan listrik kapal,Kabel komposit fotoelektrik, kabel tarikan kekuatan tinggi, kabel untuk sistem fotovoltaik, kabel untuk kendaraan transportasi kereta api dengan tegangan ac 3kv dan di bawah, kabel jaringan area lokal, kabel inverter,Kabel frekuensi radio , kabel pembangkit listrik tenaga nuklir, kabel mesin pelabuhan, kabel terisolasi mineral, kabel kapal selam dan lebih dari 100 varietas
1.30 tahun pengalaman produksi
2Sertifikasi produk: UL,CE,BV,TUV,KEMA,PSB,SABS,ABS,NK,LR,KR,GL dll
3Layanan OEM tersedia berdasarkan otorisasi resmi & hukum.
4.Sistem kontrol kualitas yang ketat.
5Pengiriman cepat dan umpan balik waktu pengiriman lebih cepat dari pesaing kami.
6. Kualitas yang sangat baik dengan harga yang wajar.
7Dukungan teknis yang kuat (data teknis, gambar, dll.)
8. Layanan kerja tim profesional untuk Anda secara aktif.
9.Stok tersedia, sampel gratis tersedia.
China Aluminium Qifan Reel and Drum mengacu pada produk kabel aluminium yang diproduksi oleh Qifan, produsen kabel Cina.Kabel biasanya disediakan dalam gulungan dan drum untuk kemudahan transportasi dan pemasanganUkuran kabel yang disebutkan, 1/0, 2/0, dan 4/0, menunjukkan ukuran American Wire Gauge (AWG) konduktor.
Berikut adalah rincian informasi yang diberikan:
Aluminium Konduktor: Kabel terbuat dari alumunium konduktor. Aluminium adalah bahan yang umum digunakan untuk konduktor listrik karena sifat ringan dan hemat biaya.memiliki ketahanan yang sedikit lebih tinggi dibandingkan dengan konduktor tembaga.
1350-H19: Istilah "1350-H19" mengacu pada kelas dan temperamen aluminium yang digunakan dalam konduktor.yang dirancang khusus untuk aplikasi listrik"H19" menunjukkan bahwa aluminium telah diproses dingin dan diperkuat untuk meningkatkan sifat mekaniknya.
Ukuran Kabel: Ukuran yang disebutkan, 1/0, 2/0, dan 4/0, adalah ukuran AWG yang umum digunakan di Amerika Utara untuk menunjukkan luas penampang konduktor.semakin kecil ukuran konduktorUkuran ini biasanya digunakan untuk aplikasi tegangan menengah hingga tinggi.
Aplikasi dan penggunaan khusus kabel ini dapat bervariasi tergantung pada industri dan kebutuhan.
Saat memilih dan menggunakan kabel, penting untuk mempertimbangkan kode listrik lokal, standar, dan peraturan untuk memastikan kepatuhan dan keselamatan.Konsultasi dengan profesional yang berkualitas atau merujuk pada lembar data produk spesifik dari produsen dapat memberikan informasi yang lebih rinci tentang spesifikasi dan aplikasi kabel.